Genuine & Original Full System and Spare Parts

RELATED PRODUCTS
ALL PRODUCTS

Source & Supply of product

MMC’s Flexi-Dip Restricted or Closed gauging tape units

  • Zero Ullage Reference
  • Custom-made sample 
  • Fast and easy interchange

Special adaptor barrels are available to other vapor-control valves

Closed or Restricted tank gauging and sounding equipment.

Portable Pressure Meters

MMC also offers a variety of additional gauging and sampling fittings such as pressure gauges for inert gas measurement, customized sounding bobs and rods, gas sampling hoses, gas sampling heads, tank bottom and zone samplers. Customized sample bottle accessories are available for use with MMC’s unique “gas-tight” product sampling system. Operators looking for to meet the sensitive requirements of “Reid Vapor Pressure” measurements can replace MMC’s standard 1-liter sampling bottle with a more appropriate container of their choice, or use a customized sample bottle and adaptor. Special Adaptor barrels can be offer to convert other maker vapor-control valves allows the valve to used with MMC Closed or Restricted Tank Gauging and Sounding equipment. Customized adaptor barrels are well-suited and verified as nil Ullage Reference will befall while analysis cargo level by supplied adaptor.

UTI-Ullage Temperature Interface Sensing Tapes

Tankers - Barges - Chemical vessels - Petro chemical Industries

Suitable for Marine & Land-Based Tank Facilities &
for Environmental Monitoring Well applications

Source & Supply of product

We represent & source most of the well-known brands in the industry. We maintain inventory on different location. This enables us to stock and deliver material worldwide with minimum delay.

Our company provides a wide range of technical items including spare parts for Instrumentation, Automation & Control for Marine, Industrial Power Plants, Offshore Vessel, Wind Power, Oil & Gas Industry.

With more than 20 years of experience in the marine market, EuroWorld is a recognized supplier for all major oil tankers, cruise and cargo & container ship operators. Our goal is to become an integral part of your supply chain management team while ensuring the highest level of customer service available.

The marine industry is time sensitive like no other industry and EuroWorld has established, tested and proven our company’s ability to respond to standard and critical material requirements as quickly as the need dictates. To best serve our marine customers, EuroWorld strives to respond to all requests for quotations within 24-72 hours.

We Maintain Inventory for Complete Systems
and Spare Parts for Immediate Delivery

Just Inform us your Difficulties Regarding OMD
and we will try Our Best to Assist You

Graviner Oil Mist Detector Mark5

Graviner Oil Mist Detector is very successful unit and it is using by hundreds of ships and we can provide you complete sales and after sales support for this OMD because we are maintaining large inventory for complete units as well spare parts also for it. we have experienced, Skilled team for carry out of function test for this unit.

Our Company Undertakes the Fast Replacement or Repair of All Spare Parts for Kidde Graviner Oil Mist Detectors.

The Technical Department, Having A Great Capability and Experience, Can Successfully Rebuild and Repair of Spare Parts. Our Company’s Workshop Equipped with All Necessary Instruments to Carryout Test and Rebuilt Complete OMD and Spare Parts.

Kidde Graviner Oil Mist Detector

We Recommend you to use for Kidde Graviner Oil Mist Detectors for Diesel Engine/Monitoring and Protection of the entire Diesel, Gas and Dual Fuel engine against severe damage.

A Serious damage may take place in case the Engine leaves its Normal Operational Parameters or an Unexpected Situation Occurs.

The Graviner Oil Mist Detector Prevents the Damage by Actual identification of Poor Quality of Operating media and Critical situations.

Schaller Visatron Oil Mist Detector

Schaller Visatron Oil Mist Detector is very successful unit and it is using by hundreds of ships and we can provide you complete sales and after sales support for this OMD because we are maintaining large inventory for complete units as well spare parts also for it. we have experienced, Skilled team for carry out of function test for this unit.

Our Company Undertakes the Fast Replacement or Repair of All Spare Parts for Schaller Visatron Oil Mist Detectors.

The Technical Department, Having A Great Capability and Experience, Can Successfully Rebuild and Repair of Spare Parts. Our Company’s Workshop Equipped with All Necessary Instruments to Carryout Test and Rebuilt Complete OMD and Spare Parts.

Schaller Oil Mist Detector

We Recommend you to use for Schaller Visatron Oil Mist Detectors for Diesel Engine/Monitoring and Protection of the entire Diesel, Gas and Dual Fuel engine against severe damage.

A Serious damage may take place in case the Engine leaves its Normal Operational Parameters or an Unexpected Situation Occurs.

The Schaller Oil Mist Detector Prevents the Damage by Actual identification of Poor Quality of Operating media and Critical situations.

We provide reconditioning and repair and servicing of oil mist detectors on board or in our instrumentation lab, with in a shorter time. Also we are keeping ready spare parts for OMD so we can deliver it immediately and these spare parts will come with installation guide so on board crew can also change the spare parts and start immediately oil mist detector. This is very successful idea because in it you can save time and long-time waiting of technicians on board.

What is Bilge Alarm and Oily Water Separator-OWS

Bilge alarm

Large commercial vessels need bilge alarms to notify the crew how much and where the bilge water is rising. These bilge alarms are electric devices that are also designed to detect leakages in the ship early before major damage is done to the vessel.

An oil content meter (OCM) is an integral part of all oily water separator (OWS) systems. Oil content meters are also sometimes referred to as oil content monitors, bilge alarms, or bilge monitors.

The OCM continuously monitors how much oil is in the water that is pumped out the discharge line of the OWS system. The OCM will not allow the oil concentration of the exiting water to be above the MARPOL standard of 15 ppm.

The oil content meter will sound an alarm if the liquid leaving the system has an unsatisfactory amount of oil in the mixture.

TAIKO KIKAI INDUSTRIES CO LTD USH-01 15 ppm Bilge Separator Separation Capacity (m³/h) 0.15 Max. Working Pressure (MPa) The product accredited for type approval by the Ministry of Land, Infrastructure and Transport Japan and in accordance with the EC Marine Equipment Directive and USCG. 〈IMO MEPC107 (49) Certification authority: MED (Europe), USCG (USA), CCS (CHINA), CR (Taiwan), JG (Japan) USH-03 to 05 15 ppm Bilge Separator Separation Capacity (m³/h) 0.25 to 0.5 Max. Working Pressure (MPa) 0.2 USH-10 to 50 15 ppm Bilge Separator Separation Capacity (m³/h) 1.0 to 5.0 Max. Working Pressure (MPa) 0.3 The product accredited for type approval by the Ministry of Land, Infrastructure and Transport Japan and in accordance with the EC Marine Equipment Directive and USCG. 〈IMO MEPC107 (49) 〉Certification authority: MED (Europe), USCG (USA), CCS (CHINA), CR (Taiwan), JG (Japan) 15PPM Oil Content Meter Brand: Deyuan Marine Item:15PPM Oil Content Meter Standard: IMO MEPC.107 (49). Certificate: CCS Delivery time: in stock Payment terms: TT,LC,Western Union,paypal, credit card Place of Origin: Zhuhai,China 15PPM Oil Content Meter The OCM-15 type Oil Content Meter, bilge water alarm device has been designed specifically for use in continuous monitoring of oil-in-bilge water, 15 ppm alarm and control of discharge, detection, memory and enquiry of alarm status. It is applicable to detect boiler condensate water. And it applies to oil and chemical industries as well. The certificate of type approval test has been obtained through comprehensive tests. This device is in accordance with the IMO-Resolution MEPC.107 (49). Main Technical Index: Oil Content Meter Measurement range: 0~199PPm Precision: 0—20PPM±2PPM, 20—199PPM±10% Oil Content Meter Alarm indication: Red LED Pressure of sample water: 0.01~0.6Mpa Runoff of sample water :0.15—4L/min Operation voltage: 220VAC, 50/60Hz Oil Content Meter Power: 25W Signal output: 4~20Ma DECKMA HAMBURG GmbH environmental-monitoring-and-protection bilge-15-ppm-monitors deckma-2005-15-ppm-bilge-alarm Brannstrom Sweden AB 15ppm Bilge Alarm Description The 15ppm bilge alarm type BILGMON 488 is type approved to meet the requirements of IMO Resolution MEPC.107(49), and with its small dimensions it is ideal also for retrofit on existing separators. The smart detachable measuring cell with wireless communication is easy to remove and replace with a newly calibrated cell, if this is preferred to having the system accuracy checked on board. On special request the BILGMON 488 is also available as a 5ppm version meeting the requirements of Class notation “Clean Design”. Technical features Oil content range 0 – 30ppm (current output 0-20mA or 4-20mA) Approvals according to MEPC.107(49) Power supply 115/230 VAC or 24V AC/DC Measuring cell with wireless communication, easy to replace Automatic fresh water flushing User interface LCD display and keypad Data retrieval via LCD display or USB port Supplied complete with 3-way flushing valve, piping set, connectors GeoRim Engineering Co Ltd Georim is a manufacturer of marine equipment based in Pusan Korea like Bilge pumps, Sludge pumps, Hydrophore units, sewage treatment equipment and is a market leader for Oily water separators (OWS). An oily water separator is a piece of equipment that separates the oily water mixtures (and other contaminants) what comes out the bilge of a vessel that could be harmful to the World’s oceans. In order to protect the environment, the IMO (International Maritime Organization) published regulations through the MEPC (Marine Environment Protection Committee) that all vessels build after 2005 had to be equipped with an Oily Water Separator that was able to achieve clean bilge water to a purity of under 15ppm of type C oil or heavily emulsified oil. These separators must also be fitted with an alarm system that will automatically shut down the pumping overboard when the quality of the water exceeds the 15-ppm limit. The OWS from Georim is equipped with a new type of bilge alarm, model GBA-155. This 15ppm bilge alarm meets the latest stringent requirements set down by IMO and MEPC regulations. The bilge alarm continuously measures the concentration of oil in water and generates an alarm when the oil concentration exceeds the 15ppm level. carry out the calibration, servicing, inspection, repair and testing of these units and in any case spares have to be used we have a full inventory of spares parts and can mobilize our well trained engineers to anywhere in the World 24 7

Oily water separator (marine)

An oily water separator (OWS) (marine) is a piece of equipment specific to the shipping or marine industry. It is used to separate oil and water mixtures into their separate components. They are found on board ships where they are used to separate oil from oily waste water such as bilge water before the waste water is discharged into the environment. These discharges of waste water must comply with the requirements laid out in MARPOL 73/78.

Bilge water is a near-unavoidable product of shipboard operations. Oil leaks from running machinery such as diesel generators, air compressors, and the main propulsion engine. Modern OWSs have alarms and automatic closure devices which are activated when the oil storage content of the waste water exceeds a certain limit (15ppm: 15 cm3 of oil in 1m3 of water).

The primary purpose of a shipboard oily water separator (OWS) is to separate oil and other contaminants that could be harmful for the oceans. The International Maritime Organization (IMO) publishes regulations through the Marine Environment Protection Committee (MEPC). On July 18, 2003, the MEPC issued new regulations that each vessel built after this date had to follow. This document is known as MEPC 107(49) and it details revised guidelines and specifications for pollution prevention equipment for machinery space bilges of ships. Each OWS must be able to achieve clean bilge water under 15 ppm of type C oil or heavily emulsified oil, and any other contaminants that may be found. All oil content monitors (OCM) must be tamper-proof. Also, whenever the OWS is being cleaned out the OCM must be active. An OWS must be able to clear out contaminants as well as oil. Some of these contaminating agents include lubricating oil, cleaning product, soot from combustion, fuel oil, rust, sewage, and several other things that can be harmful to the ocean environment.

All OWS equipment, new or old, can, in a laboratory setting, separate oil and water, do so automatically, and produce clean water for discharge overboard that contains no more than 15 parts per million oil. OWS equipment is approved by testing it with specific cocktails of mixed oil and water.

An OWS needs to be installed with an oil content meter (OCM) that samples the OWS overboard discharge water for oil content. If the oil content is less than 15 ppm, the OCM allows the water to be discharged overboard. If the oil content is higher than 15 ppm, the OCM will activate an alarm and move a three-way valve that, within a short period of time, will recirculate the overboard discharge water to a tank on the OWS suction side.

The SMART BILGE 15ppm Oil Content Monitor was developed in 2005 to meet and exceed the requirements for MEPC.107(49) regulations. The SMART BILGE is made up of 2 key components, the SMART BILGE ‘Module’ and the SMART ‘CELL’ measuring cell. The SMART CELL utilises a unique Detector Array Technology, developed by Rivertrace, allowing the OCM to analyse all three oil types (HFO, Diesel and Emulsions) simultaneously without the need for re-calibration. This innovative design allows for simple routine maintenance of the OCM while maintaining optimal conditions. Optical cell fouling is recognised as a leading cause of monitor malfunction or incorrect reading. A manual cell cleaning device is included as standard to easily enable routine maintenance. Replacement calibrated measuring cells can be purchased for easy change over on board the vessel and calibration check kits enable the crew to demonstrate the monitor is within factory calibration to PSC Surveyors. Digital Certifications Automated electronic calibration reminders Over 50 approved service centres worldwide for calibration checks and service Separate Calibrated SMART CELL to allow easy exchange Test button for demonstration of alarm points to port state control MEPC.107(49) Bilge Water Discharge Oily Water Separator Deck Drains Discharge Rig Slop Tank Discharge 5PPM Alarm – The Smart Cell Bilge Alarm is readily available as a 5ppm version if required. Autoclean – our pneumatic autoclean solution has been designed to ensure the measuring cell glass tube his kept free from fouling. Cell fouling is recognised as a leading cause of monitor malfunction. Fitting the autoclean removed the need for the ship’s crew to remember to clean the cell manually. Flowswitch – The flowswitch option has been designed to ensure that bilge water is flowing through the measuring cell when in monitoring mode. An error is shown on the display if there is no flow. The flowswitch monitors the flow of water through the cell. This ensures that the flow cannot be shut off accidentally or maliciously. In case of no flow, the Smart Bilge will close the overboard discharge valve. Hazardous Environments (Zone 1 & 2) – The SMART BILGE can be offered in an explosion proof cabinet All options can be ordered from new or retrofitted to existing Rivertrace Smart Bilge monitors. JOWA Seaguard – Bilge alarm / OCM Oil Content Meter Oily Water Treatment Systems Type approved by: DNV, USCG, RMRS, KR and CCS 0-30ppm, trend up to 40ppm Ideal for retrofit “Clean bilge” / Condensation tank monitor There are two alarms out signals which are triggered by the ppm oil content of the separator’s effluent. Adjustable between 0-15 ppm. Auto flush occurs automatically, a cleaning function designed to keep the sensor as clean as possible. The log is controlled by a signal from the separator and is saved on a removable SD card

International Convention for the Prevention of Pollution from Ships (MARPOL)

MARPOL 73/78 is the International Convention for the Prevention of Pollution from Ships, 1973 as modified by the Protocol of 1978. (“MARPOL” is short for marine pollution and 73/78 short for the years 1973 and 1978.)

MARPOL 73/78 is one of the most important international marine environmental conventions. It was designed to minimize pollution of the seas, including dumping, oil and exhaust pollution. Its stated object is to preserve the marine environment through the complete elimination of pollution by oil and other harmful substances and the minimization of accidental discharge of such substances.

We maintain Inventory for Fully Calibrated Unit
with approved certificate

IMO Approved Unit

Save Your Time & Reduce Cost Of Expenses

15ppm Oil Content Monitor/ Bilge Alarm 15ppm Oil Content Monitor/ Bilge Alarm 15ppm Oil Content Monitor/ Bilge Alarm

What is Oil Mist and Risk from it

Oil Mist Refers to Oil Droplets Suspended in the Air in the Size Range 1~10 μm.

Creation of Oil Mist

Oil Mist may form when High Pressure Fuel Oil, Lubricating Oil, Hydraulic Oil, Or Other Oil is sprayed through a Narrow Crack, Or When Leaked Oil Connects with a High Temperature Surface, Vaporizes, And Comes in Contact with Low Air Temperature.

This Happens While the Fluids Interact with The Moving Parts During Machining.

Smaller Oil Droplets Than Oil Mist is Difficult to Generate Under Normal Circumstances.

Bigger Oil Droplets Than Oil Mist Remain in Spray Form, This has the Advantage of a Higher Ignition Temperature. It Sinks Easily, Reducing Fire Hazard. Oil Mist Inside the Crankcase Can Cause A Bigger Problem.

Marine and offshore industry recommends to use oil mist detectors. They recommend oil mist detectors for safety of engine and crew onboard. While engine is running oil mist detectors checking continuously any vapor or oil mist in the crankcase of engine. Atmospheric oil mist detectors is also very important to install in open space or in framo pump room, oil purifier room, high pressure pump room, engine room. Crankcase oil mist detectors for monitoring of oil mist in engine crankcase. The G26 and VISION IIIA Ambient Oil Mist Detector is used to detect oil mist in open spaces such as pump rooms, engine rooms, and other facilities. The G26 and VISION IIIA has the several decisive advantages compared to the single point extractive sampling system. Each detector can cover a much larger area. The scanning distance of a detector is from 1 to 15 meters. The oil mist detectors has been developed for use in enclosed oil rig well head areas, generator rooms and turbine enclosures. The oil mist detector uses photoelectric cells to measure small increases in oil mist density. A motor driven fan continuously draws samples of crankcase oil mist through a measuring tube. The level model tests each crankcase in turn against a reference tube sealed with clean air Type Testing Procedure for Crankcase Oil Mist Detection and Alarm Equipment If a forced extraction of the oil mist atmosphere from the crankcase is provided (for mist detection purposes for instance), the vacuum in the crankcase is not to exceed 2.5 x 10–4 N/mm2 (2.5 m bar). Oil mist detection arrangements (or engine bearing temperature monitors or equivalent devices) are required: for alarm and slow down purposes for low speed diesel engines of 2250 kW and above or having cylinders of more than 300 mm bore for alarm and automatic shutoff purposes for medium and high-speed diesel engines of 2250 kW and above or having cylinders of more than 300 mm bore Oil mist detection arrangements are to be of a type approved by classification societies and tested in accordance with UR M67 and comply with UR M10.9 to UR M10.20. Engine bearing temperature monitors or equivalent devices used as safety devices have to be of a type approved by classification societies for such purposes. Note: For equivalent devices for high speed engines, refer to UI SC 133. The oil mist detection system and arrangements are to be installed in accordance with the engine designer’s and oil mist manufacturer’s instructions/recommendations. The following particulars are to be included in the instructions: Schematic layout of engine oil mist detection and alarm system showing location of engine crankcase sample points and piping or cable arrangements together with pipe dimensions to detector. Evidence of study to justify the selected location of sample points and sample extraction rate (if applicable) in consideration of the crankcase arrangements and geometry and the predicted crankcase atmosphere where oil mist can accumulate. The manufacturer’s maintenance and test manual. Information relating to type or in-service testing of the engine with engine protection system test arrangements having approved types of oil mist detection equipment. A copy of the oil mist detection equipment maintenance and test manual required by UR M10.9 is to be provided on board ship. Oil mist detection and alarm information is to be capable of being read from a safe location away from the engine. Each engine is to be provided with its own independent oil mist detection arrangement and a dedicated alarm. Oil mist detection and alarm systems are to be capable of being tested on the test bed and board under engine at standstill and engine running at normal operating conditions in accordance with test procedures that are acceptable to the classification society. Alarms and shutdowns for the oil mist detection system are to be in accordance with UR M35 and UR M36 and the system arrangements are to comply with UR M29 and UR The oil mist detection arrangements are to provide an alarm indication in the event of a foreseeable functional failure in the equipment and installation arrangements. The oil mist detection system is to provide an indication that any lenses fitted in the equipment and used in determination of the oil mist level have been partially obscured to a degree that will affect the reliability of the information and alarm indication. Where oil mist detection equipment includes the use of programmable electronic systems, the arrangements are to be in accordance with individual classification society requirements for such systems. Plans of showing details and arrangements of oil mist detection and alarm arrangements are to be submitted for approval in accordance with UR M44 under item 28. The equipment together with detectors is to be tested when installed on the test bed and on-board ship to demonstrate that the detection and alarm system functionally operates. The testing arrangements are to be to the satisfaction of the classification society. Where sequential oil mist detection arrangements are provided the sampling frequency and time is to be as short as reasonably practicable. Where alternative methods are provided for the prevention of the build-up of oil mist that may lead to a potentially explosive condition within the crankcase details are to be submitted for consideration of individual classification societies. The following information is to be included in the details to be submitted for consideration: Engine particulars – type, power, speed, stroke, bore and crankcase volume. Details of arrangements prevent the buildup of potentially explosive conditions within the crankcase, e.g., bearing temperature monitoring, oil splash temperature, crankcase pressure monitoring, recirculation arrangements. Evidence to demonstrate that the arrangements are effective in preventing the buildup of potentially explosive conditions together with details of in-service experience. Operating instructions and the maintenance and test instructions. Where it is proposed to use the introduction of inert gas into the crankcase to minimize a potential crankcase explosion, details of the arrangements are to be submitted to the classification society for consideration. When required by UR M10.8 or by SOLAS Reg. II-1/47.2. One oil mist detector for each engine having two independent outputs for initiating the alarm and shut-down would satisfy the requirement for independence between alarm and shut-down system. If a cross-head type engine is used as DFD, the crankcase is to be protected by oil mist detector or bearing temperature detector. Protection for piston underside space of cross-head type engine. In addition to the causes specified in 16.3.7 of IGC Code, the master gas valve is to be closed in case of any of the following: Oil mist detector or bearing temperature detector detects abnormality. Any kind of gas fuel leakage is detected. Abnormality specified in Abnormality specified in Type Testing Procedure for Crankcase Oil Mist Detection and Alarm Equipment. To specify the tests required to demonstrate that crankcase oil mist detection and alarm equipment intended to be fitted to diesel engines satisfy classification society requirements. Note: This test procedure is also applicable to oil mist detection and alarm equipment intended for gear cases. Recognized Standards. IACS Unified Requirement E10 Type Test Specification. Purpose The purpose of type testing crankcase oil mist detection and alarm equipment is seven-fold: To verify the functionality of the system. To verify the effectiveness of the oil mist detectors. To verify the accuracy of oil mist detectors. To verify the alarm set points. To verify time delays between oil mist leaving the source and alarm activation. To verify functional failure detection. To verify the influence of optical obscuration on detection. Note: Engines are to be fitted with crankcase oil mist detection and alarm equipment complying with this UR when: an application for certification of an engine is dated on/after 1 January 2007; or installed in new ships for which the date of contract for construction is on or after 1 January 2007. The requirements of 6.7 and 6.8 are to be uniformly implemented by IACS Societies from 1 January 2008. The “contracted for construction” date means the date on which the contract to build the vessel is signed between the prospective owner and the shipbuilder. For further details. regarding the date of “contract for construction”, refer to IACS Procedural Requirement (PR) No. 29. Test facilities Test houses carrying out type testing of crankcase oil mist detection and alarm equipment are to satisfy the following criteria: A full range of facilities for carrying out the environmental and functionality tests required by this procedure shall be available and be acceptable to the classification societies. The test house that verifies the functionality of the equipment is to be equipped so that it can control, measure and record oil mist concentration levels in terms of mg/l to an accuracy of ± 10% in accordance with this procedure. Functional tests All tests to verify the functionality of crankcase oil mist detection and alarm equipment are to be carried out in accordance with with an oil mist concentration in air, known in terms of mg/l to an accuracy of ±10%. The concentration of oil mist in the test chamber is to be measured in the top and bottom of the chamber and these concentrations are not to differ by more than 10%. See also 8.1.1.1. The oil mist monitoring arrangements are to be capable of detecting oil mist in air concentrations of between 0 and 10% of the lower explosive limit (LEL) or between 0 and a percentage corresponding to a level not less than twice the maximum oil mist concentration alarm set point. Note: The LEL corresponds to an oil mist concentration of approximately 50mg/l (~4.1% weight of oil in air mixture). The alarm set point for oil mist concentration in air is to provide an alarm at a maximum level corresponding to not more than 5% of the LEL or approximately 2.5mg/l. Where alarm set points can be altered, the means of adjustment and indication of set points are to be verified against the equipment manufacturer’s instructions. Where oil mist is drawn into a detector via piping arrangements, the time delay between the sample leaving the crankcase and operation of the alarm is to be determined for the longest and shortest lengths of pipes recommended by the manufacturer. The pipe arrangements are to be in accordance with the manufacturer’s instructions/recommendations. Detector equipment that is in contact with the crankcase atmosphere and may be exposed to oil splash and spray from engine lubricating oil is to be demonstrated as being such, that openings do not occlude or become blocked under continuous oil splash and spray conditions. Testing is to be in accordance with arrangements proposed by the manufacturer and agreed by the classification society. Detector equipment may be exposed to water vapor from the crankcase atmosphere which may affect the sensitivity of the equipment and it is to be demonstrated that exposure to such conditions will not affect the functional operation of the detector equipment. Where exposure to water vapour and/or water condensation has been identified as a possible source of equipment malfunctioning, testing is to demonstrate that any mitigating arrangements such as heating are effective. Testing is to be in accordance with arrangements proposed by the manufacturer and agreed by the classification society. Note: This testing is in addition to that required by 5.1.2(e) and is concerned with the effects of condensation caused by the detection equipment being at a lower temperature than the crankcase atmosphere. Detectors and alarm equipment to be tested. The detectors and alarm equipment selected for the type testing are to be selected from the manufacturer’s normal production line by the classification society witnessing the tests. Two detectors are to be tested. One is to be tested in clean condition and the other in a condition representing the maximum level of lens obscuration specified by the manufacturer. Method The following requirements are to be satisfied at type testing: Oil mist generation is to satisfy Oil mist is to be generated with suitable equipment using an SAE 80 monograde mineral oil or equivalent and supplied to a test chamber having a volume of not less than 1m3. The oil mist produced is to have a maximum droplet size of 5 µm. Note: The oil droplet size is to be checked using the sedimentation method. The oil mist concentrations used are to be ascertained by the gravimetric deterministic method or equivalent. Note: For this test, the gravimetric deterministic method is a process where the difference in weight of a 0.8 µm pore size membrane filter is ascertained from weighing the filter before and after drawing 1 liter of oil mist through the filter from the oil mist test chamber. The oil mist chamber is to be fitted with a recirculating fan. Samples of oil mist are to be taken at regular intervals and the results plotted against the oil mist detector output. The oil mist detector is to be located adjacent to where the oil mist samples are drawn off. The results of a gravimetric analysis are considered invalid and are to be rejected if the resultant calibration curve has an increasing gradient with respect to the oil mist detection reading. This situation occurs when insufficient time has been allowed for the oil mist to become homogeneous. Single results that are more than 10% below the calibration curve are to be rejected. This situation occurs when the integrity of the filter unit has been compromised and not all of the oil is collected on the filter paper. The filters require to be weighed to a precision of 0.1mg and the volume of air/oil mist sampled to 10ml. The testing is to be witnessed by authorised personnel from classification societies where type testing approval is required by a classification society. Oil mist detection equipment is to be tested in the orientation (vertical, horizontal or inclined) in which it is intended to be installed on an engine or gear case as specified by the equipment manufacturer. Type testing is to be carried out for each type of oil mist detection and alarm equipment for which a manufacturer seeks classification approval. Where sensitivity levels can be adjusted, testing is to be carried out at the extreme and mid-point level settings. Assessment Assessment of oil mist detection equipment after testing is to address the following: The equipment to be tested is to have evidence of design appraisal/approval by the classification society witnessing tests. Details of the detection equipment to be tested are to be recorded such as name of manufacturer, type designation, oil mist concentration assessment capability and alarm settings. After completing the tests, the detection equipment is to be examined and the condition of all components ascertained and documented. Photographic records of the monitoring equipment condition are to be taken and included in the report. Design series qualification. The approval of one type of detection equipment may be used to qualify other devices having identical construction details. Proposals are to be submitted for consideration. The report. The test house is to provide a full report which includes the following information and documents: Test specification. Details of equipment tested. Results of tests. Acceptance. Acceptance of crankcase oil mist detection equipment is at the discretion of individual classification societies based on the appraisal plans and particulars and the test house report of the results of type testing. The following information is to be submitted to classification societies for acceptance of oil mist detection equipment and alarm arrangements: Description of oil mist detection equipment and system including alarms. Copy of the test house report identified in 11. Schematic layout of engine oil mist detection arrangements showing location of detectors/sensors and piping arrangements and dimensions. Maintenance and test manual which is to include the following information: Intended use of equipment and its operation. Functionality tests to demonstrate that the equipment is operational and that any faults can be identified and corrective actions notified. Maintenance routines and spare parts recommendations. Limit setting and instructions for safe limit levels. Where necessary, details of configurations in which the equipment is and is not to be used. Oil Mist Detectors manufacturers kidde graviner uk specs vision korea specsvision com schaller automation Germany Daihatsu oil mist detectors DAIHATSU DIESEL MFG CO LTD dhtd co jp Johnson Controls Meiyo Electric Co Ltd VISATRON OIL MIST DETECTOR SYSTEMS Engine Protection Partner AS epp no Green Instruments green instruments com Quality Monitoring Instruments Ltd QMI oilmist com

What is Risk by Oil Mist

When the Concentration of Oil Mist Increases and Reaches the Lower Explosion Limit (LEL; 50 Mg/ℓ, As Defined by the IACS), Explosion May Occur When the Mist Contacts Surfaces of Over 200 °C (392 °F) Or a Spark.

The International Association of Classification Societies (IACS) Mandates That All Ships with A Cylinder Diameter Greater Than 300mm Or Engine Power Over 2,250 kw must be equipped with Either Bearing Temperature Detectors or Oil Mist Detectors.

Engine Safety Recommendation by using Oil Mist Detectors

We Recommend you to use Oil Mist Detector-OMD of Well-Known and Successful brands. we can suggest you for Kidde Graviner MK5, Graviner MK6, Graviner MK7 and Specs Vision Atmospheric Oil Mist Detector-AOMD & Crankcase Oil Mist Detector-COMDSchaller Visatron VN 115/87, Visatron VN 215/87, Visatron Vn 215/93 And Daihatsu MD 9M. These All Oil Mist Detector Has Recognized that Oil Mist is First Warning Of Future Lubrication Problem, and All These OMD Detect It Very Successful, False-Alarm is Safe System for Engine Protection Against Crankcase Flare-Ups began by the Ignition Of Oil Mist. Crankcase Flare-ups, which are began by Overheating Of The Moving Mechanisms Inside Engines creating a Possibly Explosive Oil Mist, have Distressing Financial Costs and Can Risk Lives. Now A Days, the Oil Mist Detection System must be Delivered and it is Preferable for Crankcase Monitoring Systems to the all engines which is using for Marine and Industrial application.

Graviner

MARK 5
Oil Mist Detector

Graviner

MARK 6
Oil Mist Detector

Graviner

MARK 7
Oil Mist Detector

Graviner Oil Mist Detector

Graviner Oil Mist Detector is very successful unit and it is using by hundreds of ships and we can provide you complete sales and after sales support for this OMD because we are maintaining large inventory for complete units as well spare parts also for it. we have experienced, Skilled team for carry out of function test for this unit.

Our Company Undertakes the Fast Replacement or Repair of All Spare Parts for Kidde Graviner Oil Mist Detectors.

The Technical Department, Having A Great Capability and Experience, Can Successfully Rebuild and Repair of Spare Parts. Our Company’s Workshop Equipped with All Necessary Instruments to Carryout Test and Rebuilt Complete OMD and Spare Parts.

We Recommend to use Kidde Graviner Oil Mist Detector

We Recommend you to use for Kidde Graviner Oil Mist Detectors for Diesel Engine/Monitoring and Protection of the entire Diesel, Gas and Dual Fuel engine against severe damage.

A Serious damage may take place in case the Engine leaves its Normal Operational Parameters or an Unexpected Situation Occurs.

The Graviner Oil Mist Detector Prevents the Damage by Actual identification of Poor Quality of Operating media and Critical situations.

Automation
&
Instrumentation
Marine
Automation & Instrumentation
Industrial
Automation & Instrumentation
Engine Safety
by
Crankcase Oil Mist Detectors
Engine Room Safety
by
Atmospheric Oil Mist Detectors
Atmospheric Oil Mist Detector
for
HPP-High Pressure Pump Room
Smoke Detection in Ship Engine Room
by
Using Atmospheric Oil Mist Detectors

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.